RG6 U/4 Trishield AP
            
            Cu/Al
        
    
    
    
    
    Application Area
     This type of RG6 cables is used for outdoor and aerial distributions of CATV networks and connections of SMATV systems
which require low attenuations. 
    
    
    
	
		Cable Construction
		
			 
		
			
				
					| Inner Conductor | 
				
					| Ø 1.02 mm Bare Copper | 
				
					| Insulation | 
				
					| Ø 4.60 mm Gas Injected Skin/Foam/Skin PE
 | 
				
					| 1st Shielding | 
				
					| Aluminum Foil Bonded to the insulation
 | 
				
					| 2nd Shielding | 
				
					| Aluminum Wire Braiding | 
				
					| 3 rd Shielding | 
				
					| Aluminum Foil Bonded to the Jacket
 | 
				
					| Suspension Wire | 
				
					| Ø 1.20mm Galvanized Steel | 
				
					| Outer Sheath | 
				
					| Ø 6.80 - 10.50 mm PE | 
				
				
			
		
	 
	
		Technical Properties
		
			 
		
			
				
					| Copper Weight | 8 kg/km | 
				
					| Min. Bending Radius | 25 mm | 
				
					| Max. Tensile Strength | 30 N | 
				
					| Operating Temperature | -40 °C ... + 70 °C | 
				
					| Packing | 300 / 500 / 1000 m | 
			
		
		Electrical Properties
		
			 
		
			
				
					| Impedance | 75+3 Ω | 
				
					| Capacitance | 53 + 2 pF/m | 
				
					| Velocity of Propagation | 82 + 2 % | 
				
					| Insulation Resistance | > 2 GΩxkm | 
				
					| Operating Voltage | 1000 V | 
				
					| Test Voltage | 2500 V | 
				
					| Inner Conductor DCR | < 22.10 Ω/km | 
			
		
		
			 
	 
	
		Attenuations (20°C)
		
			 
		
			
				
					| 5 MHz | 2.60 dB/100m | 
				
					| 50 MHz | 7.50 dB/100m | 
				
					| 230 MHz | 16.40 dB/100m | 
				
					| 470 MHz | 23.60 dB/100m | 
				
					| 860 MHz | 32.30 dB/100m | 
				
					| 1000 MHz | 34.90 dB/100m | 
				
					| 1200 MHz | 38.50 dB/100m | 
				
					| 2150 MHz | 52.40 dB/100m | 
				
					| 3000 MHz | 62.70 dB/100m | 
			
		
		Return Loss (20°C)
		
			 
		
			
				
					| 5-470 MHz | > 26 dB | 
				
					| 470-1200 MHz | > 23 dB | 
				
					| 1200-2000 MHz | > 20 dB | 
				
					| 2000-3000 MHz | > 18 dB | 
			
		
		
			 
	 
	
		Transfer Impedance
		
			 
		
		Screen Attenuation
		
			 
		
			
				
					| 30-1200 MHz | ≥ 85 dB | 
				
					| 1200-2000 MHz | ≥ 75 dB | 
				
					| 2000-3000 MHz | ≥ 65 dB 
 | 
			
		
		Standards
		
			 
		
			
				
					| Screening Class | Class A | 
				
					| EN 50117-2-5 |  | 
			
		
	 
 
	
		
			| Product Name
 | Outer Sheath Material
 | Euro Class
 | Cable Weight
 | Flame Retardancy
 | Corrosive Gases Test
 | Smoke Density
 | Download Data Sheet
 | 
		
			| RG6 U/4 AP Cu/Al PE | PE | Fca | 48 kg/km | N/A | N/A | N/A |  PE |